Welcome, Guest
login:
password:
memorize:
Register
Forgot password ?
 Product: DC/DC Converter open frame 50W
Category: DC-DC power supply OPENFRAME
DC/DC Converter open frame 50W
Series
Model No.
Output Watts
Input VoltageInput range
Polarity Protection
12
STC-1230XXX
30W continuous±12V DC
±9V ~ ±17V DC
Auto recovery
24
STC-2440XXX40W continuous±24V DC
±18V ~ ±36V DCAuto recovery
48
STC-4850XXX50W continuous±48V DC
±37V ~ ±70V DCAuto recovery
120
STC-12050XXX50W continuous±120V DC±90V ~ ±145V DCAuto recovery
220
STC-22050XXX50W continuous±220V DC±190V ~ ±245V DCAuto recovery
Note: XXX (where X=0~9) shows output voltage

ENVIRONMENTAL CONDITIONS:
●    Cooling:                           Nature convection with L bracket heatsink
●    Operating Temperature:     0°C~+65°C (Full Load)      
●    Operating Humidity:          20%~85% RH. (Non condensing)
●    Storage Temperature:       -20°C~+85°C
●    Storage Humidity:             10%~90% RH. (Non condensing)
●    Operating Altitude:            10M Below Sea level to 3000M Above Sea level

DC INPUT CHARACTERISTICS:
●    Input connector type:        15A/300V UL Approved 2-Pin Terminal
●    Input Current:                  10A(max.)    @Full Load & Low Line
●    Inrush Current:                 Less than 10A Cold start @25°C ambient

DC OUTPUT CHARACTERISTICS:
                                                         
Output voltage Load Reg Line reg Cross regOutput current min
Output current max
Output Power
Ripple & Noise
 5V ~ 125V DC±5%
±1%
±5%
0A
open
30W~50W
 
   
Total combined
continuous
max out

power
   
       
   
30W~50W    
   

OVERALL PERFORMANCE:
●    Efficiency:                                         85% typical @120V and 220V DC Full Load
●    Efficiency:                                         80% typical @48V DC Full Load

●    Efficiency:                                         70% typical @24V DC Full Load
●    Efficiency:                                         65% typical @12V DC Full Load
●    Hold up time:           
●    Rise time:
●    Power Good Signal:
●    Short Circuit Protection (SCP):           All output with SCP (shutdown and latch off)
●    Over Power Protection (OPP):            Peak power protected to 130%±10% of continuous rated power (shutdn and latch off)
●    Over Voltage Protection (OVP):          All output 130% of each output voltage

RELIABILITY:
●    MTBF (Mean Time Between Failure):   >75 000 hours @max. Load & 25°C ambient
●    Safety Standards:                             Meet IEC60950-1, EN60950-1
●    Safety Approved:       
●    EMI Compatibility (EMC) Standard:     EN55032:2015/AC:2016, CISPR32:2015, EN61000-3-2:2014, 
                                                             EN61000-3-3:2013, EN55024:2010 +A1:2015
ISOLATION:
●    INPUT and OUTPUT are isolated by transformers and optical couplers
●    Dielectric Withstand                          INPUT to OUTPUT: 1500V DC for 60 seconds
●    Dielectric Withstand                          INPUT to frame GROUND: 1500V DC for 60 seconds
●    Leakage Current:                             <0.005μA @250V DC

Input & Output Device Connector Specific:
●    Connector type:                               15A/300V UL Approved 2-Pin Terminal

Power Chassis Dimension:
●    106(L) x 59(w) x 40(H) mm / 4.17(L) x 2.32(w) x 1.57(H) Inches

Net Weight:
●    0.17 kgs / 0.374 Lbs

Gross Weight:
●    0.25 kgs / 0.55 Lbs

Packing Detail:
●    20 pcs

Measurement of Carton:
●    0.0325 m³ / 1.15 Cuft


SPECIFICATIONS:

Dealer: Synoceantech
Add to collections
Statistics


Administration