Product: ±120V DC Industrial PC 1U ATX FANLESS Redundant Power Supply |
|
|
Series
| Model No.
| Output Watts
| Input Voltage | Input range
| Polarity Protection
| 120 | STC-120550RDM | 550W continuous
| ±120V DC | ±90V ~ ±140V DC | By fuse
| ENVIRONMENTAL CONDITIONS: ● Operating Temperature: 0°C ~ +50°C (Full Load) ● Output Power: 100% @ 50°C, 70% @ 60°C ● Operating Humidity: 20%~85% RH. (Non condensing) (95% Optional) ● Storage Temperature: -20°C~+80°C ● Storage Humidity: 10%~90% RH. (Non condensing) ● Operating Altitude: 10M Below Sea level and 3000M Above Sea level
DC INPUT CHARACTERISTICS: ● Input connector type 30A/ 300V UL Approved Gold Plated Brass 1.2t/2-Pin Terminal ● Input Current 4.7A/7.33A (550W) @ Full Load High Line & Low Line ● Inrush Current Less than 20A Cold start @25°C ambient
DC OUTPUT CHARACTERISTICS:
Output Voltage | Regulation | Output Current | Ripple & Noise | Load | Line | Cross | 550W | Min | Max | +5V | ±5% | ±1% | ±5% | 0A | 20A | 50mV | +12V | 0A | 43.5A | 120mV | +3.3V | 0A | 20A | 50mV | -12V | ±8% | 0A | 0.5A | 120mV | -5V (optional)
| ±5% | 0A | 0A | 50mV | +5VSB | ±5% | 0A | 3.5A | 50mV | Maximum continuous combined load on +3.3 V & +5V DC output shall not exceed | 166 | Watts | Maximum continuous combined load on +3.3 V & +5V & 12V DC output shall not exceed | 532.5 | Maximum continuous total DC output power shall not exceed | 550 |
OVERALL PERFORMANCE: ● Efficiency 85% typical @120V DC Full Load ● Hold up time When power shut down DC output 5V must be maintain 1ms @120V DC ● Rise time ● Power Good Signal TTL Compatible signal, on delay 100~500ms, off delay 1ms min ● Short Circuit Protection (SCP) All output equipped with SCP (shutdown and latch off) ● Over Power Protection (OPP) Peak power protected to 130%±10% of continuous rated power (shutdown and latch off) ● Over Voltage Protection (OVP) +3.3V@3.6V~4.3V, +5V@5.5V~6.5V, +12V@13.2V~15.6V
RELIABILITY: ● MTBF (Mean Time Between Failure): 100 000 hours @max. Load, 120V DC & 25°C ambient ● Safety Standards: Meet IEC60950-1, EN60950-1, IEC62368-1, EN62368-1 ● Safety Approved: ● EMI Compatibility (EMC) Standard: EN55032: 2015/AC: 2016, Class A; EN55035: 2017; CISPR32: 2015 (Ed 2.0)/C1: 2016; IEC6100-4-2: 2008; EN61000-3-2: 2014; IEC6100-4-3: 2006+A1: 2007+A2: 2010; EN61000-3-3: 2013; IEC6100-4-4: 2012; IEC6100-4-5: 2014+A1: 2017; IEC6100-4-6: 2013+CAR1: 2015; IEC6100-4-8: 2009; IEC6100-4-11: 2004+A1: 2017 ISOLATION: ● INPUT and OUTPUT are isolated by transformers and optical couplers ● Dielectric Withstand: INPUT to OUTPUT: 3kV DC for 60 seconds
● Dielectric Withstand: INPUT to frame GROUND: 3kV DC for 60 seconds ● Leakage Current: <0.005μA @120V DC
LED Indicator: ● Power module 1: Green LED when Power On ● Power module 2: Green LED when Power On
Alarm function: ● In the rear panel with power failure alarm signal to indicate when power failure wire
Alarm reset switch: ● To reset by switch Output Connector specific: ● ATX 24 Pin x 1: Molex 29-01-2240 or equivalent ● +12V(P4) 4 pin x 1: Molex 39-01-2040 or equivalent ● HDD, DVD 4 pin x 4: Molex 8981-04P or equivalent ● FDD 4 pin x1: AMP171822-4 or equivalent ● Serial ATA x4: Molex 675820000 or equivalent ● CPU EPS 8 Pins x1: Molex 39-01-2080 or equivalent ● PCIe 12V 6+2 pin x 2
Standard Output Cable Length: ● 550mm ± 50mm / 21.6 Inches
PCB specific: ● 6 layer ● Copper: 3 Oz each layer ● Thickness: 1.6mm ● Material: FR4 ● PCB material origin: Taiwan
Power chassis Dimension: ● 450(L) x 200(W) x 41.3(H) mm / 17.71(L) x 7.87(W) x 1.62(H) Inches
NOTE ● Power Supply is not able to be used in stand alone application ● Use Power Supply in Power Chassis Assembly only
SPECIFICATIONS:
|
Dealer: Synoceantech |
|
Add to collections |
|
|
|