Product: ±24V DC Industrial PC PS2 4U ATX Redundant Power Supply |
|
|
Series
| Model No.
| Output Watts
| Input Voltage | Input range
| Polarity Protection
| 24 | STC-242400RD | 2400W continuous
| ±24V DC | ±18V ~ ±36V DC | Not Protected
| ENVIRONMENTAL CONDITIONS: ● Cooling: Forced Air-cooling, 80x80x25 mm Fan x 2 (With Two Ball Bearing) ● Fan brand: DELTA, NMB, SUNON, SUNON IP68 (for H version). Specifications are equivalent ● Operating Temperature: 0°C ~ +50°C (-20°C~+60°C, H version is optional) Full Load ● Output Power: 100% @ 50°C, 70% @ 60°C ● Operating Humidity: 20%~85% RH. (Non condensing) (95% Optional) ● Storage Temperature: -20°C~+80°C ● Storage Humidity: 10%~90% RH. (Non condensing) ● Operating Altitude: 10M Below Sea level and 3000M Above Sea level
DC INPUT CHARACTERISTICS: ● Input connector type 350A thickness 1.0mm / 1port for Positive terminal / 1port for Negative terminal ● Input Current 87A/173A(2400W) @ Full Load High Line & Low Line ● Inrush Current Less than 300A Cold start @25°C ambient
DC OUTPUT CHARACTERISTICS:
Output Voltage | Regulation | Output Current | Ripple & Noise | Load | Line | Cross | 2400W | Min | Max | +5V | ±5% | ±1% | ±5% | 1A | 35A | 50mV | +12V | 1A | 184A | 120mV | +3.3V | 1A | 25A | 50mV | -12V | ±8% | 0A | 1.0A | 120mV | -5V (optional)
| ±5% | 0A | 0A | 50mV | +5VSB | ±5% | 0A | 3.5A | 50mV | Maximum continuous combined load on +3.3 V & +5V DC output shall not exceed | 175 | Wattage | Maximum continuous combined load on +3.3 V & +5V & 12V DC output shall not exceed | 2382.5 | Maximum continuous total DC output power shall not exceed | 2400 |
OVERALL PERFORMANCE: ● Efficiency 70% typical @24V DC Full Load ● Hold up time When power shut down DC output 5V must be maintain 1ms @24V DC ● Rise time ● Power Good Signal TTL Compatible signal, on delay 100~500ms, off delay 1ms min ● Short Circuit Protection (SCP) All output equipped with SCP (shutdown and latch off) ● Over Power Protection (OPP) Peak power protected to 130%±10% of continuous rated power (shutdown and latch off) ● Over Voltage Protection (OVP) +3.3V@3.6V~4.3V, +5V@5.5V~6.5V, +12V@13.2V~15.6V
RELIABILITY: ● MTBF (Mean Time Between Failure): 100 000 hours @max. Load, 24V DC & 25°C ambient ● Safety Standards: Meet IEC60950-1, EN60950-1 ● Safety Approved: ● EMI Compatibility (EMC) Standard: EN55032:2015/AC:2016, CISPR32:2015, EN61000-3-2:2014, EN61000-3-3:2013, EN55024:2010 +A1:2015 ISOLATION: ● INPUT and OUTPUT are isolated by transformers and optical couplers ● Dielectric Withstand: INPUT to OUTPUT: 500V DC for 60 seconds ● Dielectric Withstand: INPUT to frame GROUND: 500V DC for 60 seconds ● Leakage Current: <0.005μA @24V DC
LED Indicator: ● Power module 1: Green LED when Power On ● Power module 2: Green LED when Power On
Alarm function: ● In the rear panel with power failure alarm signal to indicate when power failure wire
Alarm reset switch: ● To reset by switch
Output Connector specific: ● ATX 24 Pin x 1: Molex 29-01-2240 or equivalent ● HDD, DVD 4 pin x 4: Molex 8981-04P or equivalent ● FDD 4 pin x 1: AMP171822-4 or equivalent ● Serial ATA x 2: Molex 675820000 or equivalent ● CPU EPS 8 Pins x 2: Molex 39-01-2080 or equivalent ● PCIe x 10
Standard Output Cable Length: ● 500 mm / 19.68 Inches
PCB specific: ● 4 layer ● Copper: 3 Oz ● Thickness: 1.6 mm ● Material: FR4 ● PCB material origin: Taiwan
Power chassis Dimension: ● 530(L) x 167(W) x 189(H) mm / 20.87(L) x 6.57(W) x 7.44(H) Inches
Rackmount Chassis Solution: ● 4U IPC Chassis
Screw hole: ● Front panel with 6 screw holes ● Rear panel bracket with screw holes
Net Weight: ● 23 kg / 50.70 lbs
Gross Weight: ● 25 kg / 55.10 lbs
Packing Detail ● 1 pc ● 26 kg / 57.32 lbs
Measurement of Carton ● 0.045 m3 / 1.59 Cuft